Vulnerability

CVE-2026-107612

highCVSS 3.1 7.8Published 8 Oct 2026

A plain-language summary of this CVE is being written; the description below is the NVD's own text.

Description

Incorrect permission assignment in GlavSoft TightVNC Server for Windows before 2.8.88 allows a local authenticated user to read or overwrite the inter-process communication handles used between the TightVNC service and its desktop server process. The named shared memory segment in the Global\ namespace that carries the pipe HANDLE values is created with a NULL DACL, and its name is derived from a time-seeded srand(time(0)) value that is predictable to one-second granularity. A low-privileged local process can open the mapping and tamper with the IPC channel of a service running as SYSTEM, potentially leading to disclosure of session data, privilege escalation, or denial of service.

Affected products

The NVD has not attached product data to this record yet; the description names what is affected.