A plain-language summary of this CVE is being written; the description below is the NVD's own text.
Description
In the Linux kernel, the following vulnerability has been resolved:
w1: therm: Fix off-by-one buffer overflow in alarms_store
The sysfs buffer passed to alarms_store() is allocated with 'size + 1' bytes and a NUL terminator is appended. However, the 'size' argument does not account for this extra byte. The original code then allocated 'size' bytes and used strcpy() to copy 'buf', which always writes one byte past the allocated buffer since strcpy() copies until the NUL terminator at index 'size'.
Fix this by parsing the 'buf' parameter directly using simple_strtoll() without allocating any intermediate memory or string copying. This removes the overflow while simplifying the code.
Affected products
The NVD has not attached product data to this record yet; the description names what is affected.
References
- git.kernel.org /stable/c/060b08d72a38b158a7f850d4b83c17c2969e0f6b
- git.kernel.org /stable/c/49ff9b4b9deacbefa6654a0a2bcaf910c9de7e95
- git.kernel.org /stable/c/6a5820ecfa5a76c3d3e154802c8c15f391ef442e
- git.kernel.org /stable/c/6fd6d2a8e41b7f544a4d26cbd60bedf9c67893a0
- git.kernel.org /stable/c/761fcf46a1bd797bd32d23f3ea0141ffd437668a
- git.kernel.org /stable/c/b3fc3e1f04dcc7c41787bbf08a6e0d2728e022cf
- git.kernel.org /stable/c/e6b2609af21b5cccc9559339591b8a2cbf884169
- cert-portal.siemens.com /productcert/html/ssa-019113.html
- cert-portal.siemens.com /productcert/html/ssa-457936.html