Vulnerability

CVE-2025-52985

mediumCVSS 4.0 6.9Published 11 Jul 2025

A plain-language summary of this CVE is being written; the description below is the NVD's own text.

Description

A Use of Incorrect Operator

vulnerability in the Routing Engine firewall of Juniper Networks Junos OS Evolved allows an unauthenticated, network-based attacker to bypass security restrictions.

When a firewall filter which is applied to the lo0 or re:mgmt interface references a prefix list with 'from prefix-list', and that prefix list contains more than 10 entries, the prefix list doesn't match and packets destined to or from the local device are not filtered.

This issue affects firewall filters applied to the re:mgmt interfaces as input and output, but only affects firewall filters applied to the lo0 interface as output. This issue is applicable to IPv4 and IPv6 as a prefix list can contain IPv4 and IPv6 prefixes. This issue affects Junos OS Evolved:

* 23.2R2-S3-EVO versions before 23.2R2-S4-EVO, * 23.4R2-S3-EVO versions before 23.4R2-S5-EVO, * 24.2R2-EVO versions before 24.2R2-S1-EVO, * 24.4-EVO versions before 24.4R1-S3-EVO, 24.4R2-EVO.

This issue doesn't affect Junos OS Evolved versions before 23.2R1-EVO.