A plain-language summary of this CVE is being written; the description below is the NVD's own text.
Description
In the CGM CLININET application server, multiple processes responsible for HL7 communication with external systems run with root privileges while processing untrusted data received from those external systems. An attacker in adjacent network able to send data to these HL7 communication processes can achieve remote code execution with root privileges.
The vulnerability was confirmed to affect versions up to 2026.MS3 but later versions may also be vulnerable.
Affected products
The NVD has not attached product data to this record yet; the description names what is affected.
Weakness type
References
- cert.pl /en/posts/2026/10/CVE-2025-30043/
- www.cgm.com /pol_pl/products/szpital/cgm-clininet.html
Ingati scans your site every week and tells you when a CVE like this one affects something it found there.