A plain-language summary of this CVE is being written; the description below is the NVD's own text.
Description
A vulnerability has been identified in SINUMERIK Analyse MyCondition (All versions), SINUMERIK Analyze MyPerformance (All versions), SINUMERIK Analyze MyPerformance /OEE-Monitor (All versions), SINUMERIK Analyze MyPerformance /OEE-Tuning (All versions), SINUMERIK Integrate Client 02 (All versions >= V02.00.12 < 02.00.18), SINUMERIK Integrate Client 03 (All versions >= V03.00.12 < 03.00.18), SINUMERIK Integrate Client 04 (V04.00.02 and all versions >= V04.00.15 < 04.00.18), SINUMERIK Integrate for Production 4.1 (All versions < V4.1 SP10 HF3), SINUMERIK Integrate for Production 5.1 (V5.1), SINUMERIK Manage MyMachines (All versions), SINUMERIK Manage MyMachines /Remote (All versions), SINUMERIK Manage MyMachines /Spindel Monitor (All versions), SINUMERIK Manage MyPrograms (All versions), SINUMERIK Manage MyResources /Programs (All versions), SINUMERIK Manage MyResources /Tools (All versions), SINUMERIK Manage MyTools (All versions), SINUMERIK Operate V4.8 (All versions < V4.8 SP8), SINUMERIK Operate V4.93 (All versions < V4.93 HF7), SINUMERIK Operate V4.94 (All versions < V4.94 HF5), SINUMERIK Optimize MyProgramming /NX-Cam Editor (All versions). Due to an error in a third-party dependency the ssl flags used for setting up a TLS connection to a server are overwitten with wrong settings. This results in a missing validation of the server certificate and thus in a possible TLS MITM szenario.
Affected products
From the NVD's configuration data (CPE), vendor first.
- Siemens sinumerik analyse mycondition firmware, sinumerik analyse mycondition, sinumerik analyze myperformance firmware, sinumerik analyze myperformance, sinumerik integrate client firmware, sinumerik integrate client, sinumerik integrate for production firmware, sinumerik integrate for production, sinumerik manage mymachines firmware, sinumerik manage mymachines, sinumerik manage myprograms firmware, sinumerik manage myprograms, sinumerik manage myresources firmware, sinumerik manage myresources, sinumerik manage mytools firmware, sinumerik manage mytools, sinumerik operate firmware, sinumerik operate, sinumerik optimize myprogramming firmware, sinumerik optimize myprogramming
Weakness type
References
- cert-portal.siemens.com /productcert/pdf/ssa-729965.pdf
- us-cert.cisa.gov /ics/advisories/icsa-21-194-04
Ingati scans your site every week and tells you when a CVE like this one affects something it found there.
Start scanning