A plain-language summary of this CVE is being written; the description below is the NVD's own text.
Description
Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.
Affected products
From the NVD's configuration data (CPE), vendor first.
- Hitachienergy relion 670 firmware, relion 670, relion 650 firmware, relion 650, relion sam600-io firmware, relion sam600-io, rtu500 firmware, rtu500, reb500 firmware, reb500, fox615 tego1 firmware, fox615 tego1, modular switchgear monitoring firmware, modular switchgear monitoring, gms600 firmware, gms600, pwc600 firmware, pwc600
Weakness type
References
- search.abb.com /library/Download.aspx
- search.abb.com /library/Download.aspx
- search.abb.com /library/Download.aspx
- search.abb.com /library/Download.aspx
- search.abb.com /library/Download.aspx
- search.abb.com /library/Download.aspx
- search.abb.com /library/Download.aspx
Ingati scans your site every week and tells you when a CVE like this one affects something it found there.