Vulnerability

CVE-2020-28395

mediumCVSS 3.1 5.9Published 12 Jan 2021

A plain-language summary of this CVE is being written; the description below is the NVD's own text.

Description

A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.

Affected products

From the NVD's configuration data (CPE), vendor first.

  • Siemens scalance xr324-12m firmware, scalance xr324-12m, scalance xr324-12m ts firmware, scalance xr324-12m ts, scalance xr324-4m eec firmware, scalance xr324-4m eec, scalance xr324-4m poe firmware, scalance xr324-4m poe, scalance xr324-4m poe ts firmware, scalance xr324-4m poe ts, scalance xr324wg firmware, scalance xr324wg, scalance xr326-2c poe wg firmware, scalance xr326-2c poe wg, scalance xr328-4c wg firmware, scalance xr328-4c wg