Vulnerability

CVE-2019-13924

mediumCVSS 3.1 5.4Published 11 Feb 2020

A plain-language summary of this CVE is being written; the description below is the NVD's own text.

Description

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Affected products

From the NVD's configuration data (CPE), vendor first.

  • Siemens scalance xc-200 firmware, scalance xc-200, scalance xf-200 firmware, scalance xf-200, scalance xp-200 firmware, scalance xp-200, scalance x-200irt firmware, scalance x-200irt, scalance xb-200 firmware, scalance xb-200, scalance xr-300wg firmware, scalance xr-300wg, scalance x-300 firmware, scalance x-300, scalance xr-300 firmware, scalance xr-300

Weakness type

References

Ingati scans your site every week and tells you when a CVE like this one affects something it found there.

Start scanning